Chimney Seismic Retrofit in Corona
Ask About This Job
Give the address, the kind of fireplace and what it is doing. A Danforth tech rings back to confirm this is the right visit.
The Work, Part by Part
Prefab metal chimneys are light and flexible, but plenty of homes we visit still have a brick stack, and brick fares badly in a quake. Options range from steel bracing back to the roof framing, to straps at ceiling and floor lines, to taking the brick down to the roofline and rebuilding above it as a framed chase over listed metal pipe. We look at the brick and the framing first, then set out which option fits.
Why Brick Is the Concern, Not the Metal Pipe
Most houses in Corona built after the early 1980s have a factory-built fireplace and a metal pipe inside a wood chase. That chimney is light, framed into the house wall, and sways along with it; after a shake the things to check are pipe joints that may have pulled apart and a chase top that may have shifted, not a stack about to fall. Older houses are different. A brick chimney from the 1950s or 1960s, the kind found across older Anaheim and central Corona, was usually built without steel inside it and is fastened to the house only lightly. When the ground moves, the brick above the roof rocks on the joint where it leaves the roof deck. Broken chimneys lying on roofs and lawns were a common sight after past Southern California quakes, and that weak joint is the reason.
Making a brick chimney safer comes down to holding the upper stack, tying it to the house, or reducing how much of it there is. Holding means a steel frame or brace fixed to the stack above the roof and carried down into the roof structure. Tying means steel anchors at the levels where the chimney passes floors and ceilings, fastened into the framing so the brick and the house move as one. Reducing means removing the brick above the roof, closing or capping what remains, and often finishing with a listed metal chimney in a framed chase, the same type of system newer houses already have. Some chimneys get one of these and some get two. None of them is useful on brick that is already loose, which has to be rebuilt first before any steel goes on.
The Visit and the Written Scope
A seismic visit starts with the chimney's condition, because the right option depends on whether the brick is sound. We look at the stack above the roof for loose courses and cracks at the roofline, at the attic for the space between the brick and the framing and any ties already there, and at the firebox and smoke chamber for cracking that suggests earlier movement. On houses with a factory-built chimney, the same visit checks the pipe joints, firestops and chase framing instead. Then we write a scope that names the option we suggest for that chimney, what it involves on the roof and in the attic, how the flue and fireplace will work afterward, and its price. We do not cite code sections or promise any rebate, permit outcome or result with an insurer.
Owners usually call at one of three points: after a shake they felt, when buying an older house, or when a roof is being replaced and the chimney is exposed anyway. That last one is a good moment, because removing brick to the roofline or bolting on a brace is easier with the roof open, and the roofer can tie the new work in. If the fireplace is no longer used for wood, reducing the stack and converting to a sealed gas insert, $2,700 to $5,450 installed, is a common pairing, since the insert's venting does not depend on the brick above the roof. Homes in Diamond Bar and Tustin with brick chimneys can book the same visit. Use the form to note the house's age, whether the chimney is brick or a sided box, and any cracks you have noticed.
How Danforth Chimney Care Handles It
Label Read First
The model on the plate decides which parts fit
Manual on Hand
Clearances and parts checked against the maker's book
Written Price
Part numbers and costs on paper before anything is ordered
Photo Report
Each finding shown with a picture and a plain note
Towns where we offer chimney seismic retrofit
Pick your town for notes on the housing there and how this job usually goes on those streets.
Danforth has no listing under that name for this service. Try another spelling, or choose a nearby town below.
Other Danforth Services
Chimney Sweep
Soot and creosote cleared from metal pipe or clay flue, then each joint and spacer looked over while the inside is clean.
Open →Chimney Inspection
The whole venting system measured against its maker's listing, from firebox panels up to the chase top, at the NFPA 211 level it needs.
Open →Chimney Repair
Metal chimney systems repaired with parts their maker lists, and brick stacks given mortar and crown work.
Open →Fireplace Inspection
A room side check of prefab or masonry fireplaces: panels, screens, doors, damper, hearth and the clearances the maker sets.
Open →Fireplace Repair
Cracked panels, warped grates, failed dampers and missing screens on prefab fireboxes, fixed with parts listed for that model.
Open →Chimney Level 2 Inspection
Video of the full pipe or flue, plus attic and chase checks, written up for buyers, sellers, agents and insurers.
Open →Chimney Cap Installation
Termination caps matched to the pipe brand on prefab systems, and mesh-sided stainless or copper caps on brick flues.
Open →Chimney Flashing Repair
Roof seals at brick stacks and framed chases renewed, after the cricket, siding and chase top are ruled in or out.
Open →Chimney Masonry Repair
Brick, mortar and crown work for the brick stacks that stand alongside the many prefab chimneys we look after.
Open →Chimney Rebuilds
Failing brick above the roof rebuilt with steel and ties, or swapped for a framed chase holding a listed metal flue.
Open →Fireplace Cleaning
Ash, soot and glass haze cleared from the firebox, doors and hearth, without scrubbing soft refractory panels thin.
Open →Gas Fireplace Cleaning
Yearly service for sealed gas units and log sets: burner, pilot, glass, log layout and the vent cap outside.
Open →Gas Fireplace Repair
No flame, short burns and dead remotes on gas units, traced with a meter and fixed using the maker's own parts.
Open →Fireplace Remodel
Surrounds, mantels and hearths for prefab units, held to the clearance distances printed in the unit's manual.
Open →Fireplace Inserts
Gas and wood inserts set into existing fireboxes, after we confirm a prefab unit is listed to take one.
Open →Pellet Stove Repair
Auger motors, igniters, fans, sensors and boards tested in turn, then every vent pipe joint sealed tight.
Open →Wood Stove Repair
Door seals, baffles, firebrick, catalysts and stovepipe on freestanding wood stoves, renewed with parts made for the model.
Open →Gas Logs
Log sets for wood-burning fireboxes, chosen only after we confirm the unit's listing permits gas.
Open →Chimney Crown Repair
Cracked mortar tops on brick chimneys sealed or recast with a lip, so rain stays off the brick face.
Open →Dryer Vent Cleaning
Lint cleared from the dryer duct and the outside hood, with plastic connectors swapped for metal.
Open →Chimney Liner Installation
Stainless liners for cracked clay flues and new inserts, with the diameter set by the appliance outlet.
Open →Chimney Leak Repair
Water in a chase or around a brick stack traced to its entry point, then fixed at the top, seams, flashing or siding.
Open →Chimney Waterproofing
A breathable repellent for repaired brick chimneys, and sealed seams and tops for framed chases.
Open →Chimney Damper Repair
Stuck, rusted or broken dampers on prefab and brick fireplaces fixed with matched parts or a cable-operated top damper.
Open →Chimney Chase Cover
Rusted chase tops on framed chimneys replaced with made-to-measure stainless, cross-broken so water runs off.
Open →