The Work, Part by Part

Fixing a factory-built firebox is a parts job, not a mortar job. Refractory panels come cut for each model, dampers and screens belong to the unit, and a homemade patch can void the listing. We read the label, order the matching parts and fit them. Where the maker has stopped supplying a model or the steel shell has burned through, we tell you plainly and price a replacement instead. Brick fireboxes get firebrick and mortar repairs.

Refractory panel sets ordered by model number
Damper blades and handles matched to the unit
Mesh screens and doors from the listed range
Burned through shells flagged for replacement
Firebrick and mortar work on brick fireplaces
Written price before any part is ordered

The Repairs a Metal Firebox Needs Most

Refractory panels come first. The cast liners on the back, sides and floor of a steel firebox take the heat so the steel does not, and they wear out: cracks spread, corners break off, a log thrown in hard punches a hole. Once a crack opens past what the maker allows or the steel shows through, the panel is replaced with the one made for that model, shaped at the factory to fit its clips. Refractory cement smeared over the gap is not an approved fix on most units and tends to fall out within a season. Dampers come next. On a prefab unit the damper is a steel plate on a rod or a spring, built into the top of the firebox, and its handle, chain or spring usually gives out long before the plate does. Replacement linkages are made for one model and rarely fit another.

Then the smaller parts. Grates warp and sag until the fire sits against the back panel, which is how many panels crack in the first place. Glass doors lose their latches and gaskets, and the glass itself can shatter if a door is closed on a hot fire with cold air behind it. Mesh screens tear. Louvers bend and stop letting air move. On units with a fan kit, the blower bearings start to grind and the switch that turns the fan on with heat fails. Each of these has a number in the maker's parts list, and for most common brands the parts are still made or have a listed replacement. When we open a fireplace in Corona or Diamond Bar we write down the plate, check the parts list, and price the repair from parts we know belong in that box.

When a Prefab Unit Should Be Replaced, Not Repaired

Some damage ends the life of a factory-built firebox. Steel that has burned through, an outer shell rusted out by years of water coming down a failed chase top, or a box warped so far the panels no longer sit in their clips cannot be brought back to the listing. Welding a patch into a listed firebox turns it into something nobody tested. The same goes for a unit whose maker closed decades ago and whose panels and dampers are not sold in any form. In those cases we tell you so, and we lay out the common paths. One is a new factory-built fireplace with its matching chimney, set in the same opening. Another, where the steel is still sound but the parts are gone, is a gas insert listed for factory-built fireplaces, which costs $2,700 to $5,450 with installation. If neither suits, the fireplace can be closed off safely.

Pricing follows the parts list. A single panel, a damper linkage or a door latch is a small job, often finished in one visit once the part is on hand. A full set of panels with a grate and a door gasket is larger. We give the price in writing with each part named, so you can check it against the maker's list, and we order only after you agree. Many common panels and linkages are stocked by distributors in Southern California; some older models take longer to source, and we tell you that at the start instead of fitting something that merely fits. When you send the form, mention the brand if you can read it on the plate or the grille, what is wrong, and when it started. We work in Anaheim, Tustin and Diamond Bar as well as Corona.

How Danforth Chimney Care Handles It

Label Read First

The model on the plate decides which parts fit

Manual on Hand

Clearances and parts checked against the maker's book

Written Price

Part numbers and costs on paper before anything is ordered

Photo Report

Each finding shown with a picture and a plain note

Other Danforth Services

Chimney Sweep

Soot and creosote cleared from metal pipe or clay flue, then each joint and spacer looked over while the inside is clean.

Open →

Chimney Inspection

The whole venting system measured against its maker's listing, from firebox panels up to the chase top, at the NFPA 211 level it needs.

Open →

Chimney Repair

Metal chimney systems repaired with parts their maker lists, and brick stacks given mortar and crown work.

Open →

Fireplace Inspection

A room side check of prefab or masonry fireplaces: panels, screens, doors, damper, hearth and the clearances the maker sets.

Open →

Chimney Level 2 Inspection

Video of the full pipe or flue, plus attic and chase checks, written up for buyers, sellers, agents and insurers.

Open →

Chimney Cap Installation

Termination caps matched to the pipe brand on prefab systems, and mesh-sided stainless or copper caps on brick flues.

Open →

Chimney Flashing Repair

Roof seals at brick stacks and framed chases renewed, after the cricket, siding and chase top are ruled in or out.

Open →

Chimney Masonry Repair

Brick, mortar and crown work for the brick stacks that stand alongside the many prefab chimneys we look after.

Open →

Chimney Rebuilds

Failing brick above the roof rebuilt with steel and ties, or swapped for a framed chase holding a listed metal flue.

Open →

Fireplace Cleaning

Ash, soot and glass haze cleared from the firebox, doors and hearth, without scrubbing soft refractory panels thin.

Open →

Gas Fireplace Cleaning

Yearly service for sealed gas units and log sets: burner, pilot, glass, log layout and the vent cap outside.

Open →

Gas Fireplace Repair

No flame, short burns and dead remotes on gas units, traced with a meter and fixed using the maker's own parts.

Open →

Fireplace Remodel

Surrounds, mantels and hearths for prefab units, held to the clearance distances printed in the unit's manual.

Open →

Fireplace Inserts

Gas and wood inserts set into existing fireboxes, after we confirm a prefab unit is listed to take one.

Open →

Pellet Stove Repair

Auger motors, igniters, fans, sensors and boards tested in turn, then every vent pipe joint sealed tight.

Open →

Wood Stove Repair

Door seals, baffles, firebrick, catalysts and stovepipe on freestanding wood stoves, renewed with parts made for the model.

Open →

Gas Logs

Log sets for wood-burning fireboxes, chosen only after we confirm the unit's listing permits gas.

Open →

Chimney Seismic Retrofit

Brick chimneys braced, strapped or rebuilt lighter above the roof, so a strong quake is less likely to drop them.

Open →

Chimney Crown Repair

Cracked mortar tops on brick chimneys sealed or recast with a lip, so rain stays off the brick face.

Open →

Dryer Vent Cleaning

Lint cleared from the dryer duct and the outside hood, with plastic connectors swapped for metal.

Open →

Chimney Liner Installation

Stainless liners for cracked clay flues and new inserts, with the diameter set by the appliance outlet.

Open →

Chimney Leak Repair

Water in a chase or around a brick stack traced to its entry point, then fixed at the top, seams, flashing or siding.

Open →

Chimney Waterproofing

A breathable repellent for repaired brick chimneys, and sealed seams and tops for framed chases.

Open →

Chimney Damper Repair

Stuck, rusted or broken dampers on prefab and brick fireplaces fixed with matched parts or a cable-operated top damper.

Open →

Chimney Chase Cover

Rusted chase tops on framed chimneys replaced with made-to-measure stainless, cross-broken so water runs off.

Open →

Prefab fireplace guides from Danforth Chimney Care