The Work, Part by Part

Remodeling around a factory-built fireplace has rules a brick one does not. The manual sets how close wood trim and a mantel may sit, which facing materials may touch the metal front, and whether the louvers must stay open. We pull the manual for your model before design starts, then build the surround, hearth and mantel to it. If the unit itself is worn out, swapping it comes first.

Manual for the unit found before design
Mantel height and depth set to the listed limits
Noncombustible facing where the front gets hot
Louvers and vents left clear
Tile, stone or plaster finishes
Worn units swapped before the new face goes on

What the Metal Unit Allows Around It

The typical remodel request in Corona and Diamond Bar involves a 1980s or 1990s builder fireplace: a black metal front, brass trim, a ceramic tile border and a wood shelf above. Owners want stone floor to ceiling, a floating shelf, a TV above, or a cleaner modern face. All of that is possible on many units, but the fireplace's manual sets what may touch the metal front and whether the louvers and the top vent may be covered, and it gives numbers for wood trim and a mantel shelf, measured from the opening. Facing material is usually limited to noncombustible stone, tile or brick, set so it does not block cooling air. Before any design talk starts, we read the plate, find the manual and mark those limits on the wall in pencil, so every choice after that is made inside them.

TVs are the common sticking point. Heat rising off the face of a wood-burning prefab unit can be enough to damage a set mounted close above it, and some manuals require a shelf or a heat deflector between the two. Stone weight is another. A full-height stone wall is built on its own framing and backer, not hung on the fireplace face, and the floor under it has to carry the load. We also keep track of what is inside the wall: the chimney pipe and its firestop run up behind the facing, and nothing may be screwed into them. If the remodel is a chance to change fuel, we set out the gas options side by side: a log set listed for the box, a gas insert, or a new direct vent unit in place of the old one, each with what it means for the facing.

From Measurements to a Written Plan

A remodel visit starts with a tape and the manual, not samples. We record the face dimensions, the louver positions and the trim limits the manual gives, then sketch where stone or tile may go and where it may not. If the old unit is worn or its parts are hard to get, swapping it during the remodel may cost less over the years than refacing around it, and we price both. If the plan is a fireplace in a room that has none today, a direct vent gas unit with its venting costs $4,350 to $8,700. Most refacing jobs have no published price because the material choice drives the cost, and the written plan lists facing, backer, shelf, hearth pad and any fireplace work as separate lines so you can trade one choice against another before anything is ordered.

Timing works around the house. Facing work makes dust, so we close off the room and protect the floor, and stone or tile that needs to cure means the fireplace sits unused for a stretch afterward. Most owners in Tustin and Anaheim schedule remodels in spring or summer for that reason. We do not do whole-room design, but we work alongside a designer or contractor if you have one, and we hand over the manual limits in writing so everyone builds to the same numbers. When you send the form, describe the fireplace as it is today, the look you are after, and whether a gas line already reaches it. The first step after that is a visit with a tape measure and the manual, and the plan and price follow from what that visit finds.

How Danforth Chimney Care Handles It

Label Read First

The model on the plate decides which parts fit

Manual on Hand

Clearances and parts checked against the maker's book

Written Price

Part numbers and costs on paper before anything is ordered

Photo Report

Each finding shown with a picture and a plain note

Other Danforth Services

Chimney Sweep

Soot and creosote cleared from metal pipe or clay flue, then each joint and spacer looked over while the inside is clean.

Open →

Chimney Inspection

The whole venting system measured against its maker's listing, from firebox panels up to the chase top, at the NFPA 211 level it needs.

Open →

Chimney Repair

Metal chimney systems repaired with parts their maker lists, and brick stacks given mortar and crown work.

Open →

Fireplace Inspection

A room side check of prefab or masonry fireplaces: panels, screens, doors, damper, hearth and the clearances the maker sets.

Open →

Fireplace Repair

Cracked panels, warped grates, failed dampers and missing screens on prefab fireboxes, fixed with parts listed for that model.

Open →

Chimney Level 2 Inspection

Video of the full pipe or flue, plus attic and chase checks, written up for buyers, sellers, agents and insurers.

Open →

Chimney Cap Installation

Termination caps matched to the pipe brand on prefab systems, and mesh-sided stainless or copper caps on brick flues.

Open →

Chimney Flashing Repair

Roof seals at brick stacks and framed chases renewed, after the cricket, siding and chase top are ruled in or out.

Open →

Chimney Masonry Repair

Brick, mortar and crown work for the brick stacks that stand alongside the many prefab chimneys we look after.

Open →

Chimney Rebuilds

Failing brick above the roof rebuilt with steel and ties, or swapped for a framed chase holding a listed metal flue.

Open →

Fireplace Cleaning

Ash, soot and glass haze cleared from the firebox, doors and hearth, without scrubbing soft refractory panels thin.

Open →

Gas Fireplace Cleaning

Yearly service for sealed gas units and log sets: burner, pilot, glass, log layout and the vent cap outside.

Open →

Gas Fireplace Repair

No flame, short burns and dead remotes on gas units, traced with a meter and fixed using the maker's own parts.

Open →

Fireplace Inserts

Gas and wood inserts set into existing fireboxes, after we confirm a prefab unit is listed to take one.

Open →

Pellet Stove Repair

Auger motors, igniters, fans, sensors and boards tested in turn, then every vent pipe joint sealed tight.

Open →

Wood Stove Repair

Door seals, baffles, firebrick, catalysts and stovepipe on freestanding wood stoves, renewed with parts made for the model.

Open →

Gas Logs

Log sets for wood-burning fireboxes, chosen only after we confirm the unit's listing permits gas.

Open →

Chimney Seismic Retrofit

Brick chimneys braced, strapped or rebuilt lighter above the roof, so a strong quake is less likely to drop them.

Open →

Chimney Crown Repair

Cracked mortar tops on brick chimneys sealed or recast with a lip, so rain stays off the brick face.

Open →

Dryer Vent Cleaning

Lint cleared from the dryer duct and the outside hood, with plastic connectors swapped for metal.

Open →

Chimney Liner Installation

Stainless liners for cracked clay flues and new inserts, with the diameter set by the appliance outlet.

Open →

Chimney Leak Repair

Water in a chase or around a brick stack traced to its entry point, then fixed at the top, seams, flashing or siding.

Open →

Chimney Waterproofing

A breathable repellent for repaired brick chimneys, and sealed seams and tops for framed chases.

Open →

Chimney Damper Repair

Stuck, rusted or broken dampers on prefab and brick fireplaces fixed with matched parts or a cable-operated top damper.

Open →

Chimney Chase Cover

Rusted chase tops on framed chimneys replaced with made-to-measure stainless, cross-broken so water runs off.

Open →
Call (951) 523-0112